NFPA 1901 CERTIFIED REGULATOR CONTROLLED FILL STATION - SLIDING DOOR FILL-KAT LINEAR FILL STATION, PLC CONTROLLED
The FILL-KAT series SCBA recharging system is a free standing and complete filling/de-fragmentation station for 2216, 3000, 4500 and 5500 psig cylinders. The SCBA refilling station is of a fully enclosed design to contain a SCBA cylinder failure or ruptured SCBA fill hose.
- The Jordair FILL-KAT series fill stations are the safest and most technically advanced filling stations offered in Canada for the containment and recharging of SCBA cylinders.
- Linear filling of SCBA cylinders with optional compressor interface for integrated compressor and fill station operation.
- Operator control is optional as open use or overseen by a password system which ensures only fully trained operators are filling the SCBA cylinders.
- The fill station is set to fill at the CSA standard rate of exactly 300 PSIG per minute; other fill rates up to 1500 PSIG per minute can be selected by entering the pass code and selecting the new fill rate displayed on the screen. The system defaults to the 300 PSIG/min rate.
- A fully enclosed SCBA containment system that encloses both the SCBA cylinders and the filling hoses with a sliding front access door. The door must be closed and locked before SCBA cylinders can be recharged.
- A toggle activated valve stops air flow to the filling points when the door is opened.
- Sliding front access door is 1⁄2” plate steel for optimum operator safety.
- The front access door is held in the closed position by a spring loaded pin type door lock.
- Heavy wall schedule 40 steel 8” pipe used to contain the SCBA cylinders within the recharge station.
- Anti-abrasion collars and liners in the SCBA containment sleeves to protect the exterior of the SCBA cylinders
from abrasion damage during the filling process
- 7000 psig inlet ball type shut off valve to isolate the recharging station from the compressor and air storage
cylinders.
- One anodised aluminum, self-venting and adjustable regulator with operating pressures from 0 to 7,000-PSIG
inlets and 0 to 7,000-PSIG outlet pressures.
- The fill station has one fill hose per fill position and a quick disconnect to allow fill adapter changes for different
pressures.
- When different filling pressures are required, a manual selection valve provides for the desired pressure and
safety relief valve over-fill protection.
- The final fill pressure is selected on the touch screen when the FILL-KAT is ordered with more than one fill
pressure option.
- Panel mounted SCBA cylinder ball type shut off valves for 2216, 3000, 4500 and 5500 PSIG fill positions.
- SCBA recharge assemblies are supplied for the selected 2216, 3000, 4500 or 5500 psig filling.
- A CRN certified safety relief valve is set for 2400, 3200, 4700 and 5700 psig to protect the filling of the 2216,
3000, 4500 and 5500 psig SCBA or SCUBA cylinders.
- The fill station has removable service access panels for ease of service of the pressure components.
- All pressure piping conforms to ASME code B31.1 and B31.3.
- All D series fill stations have been third party tested and certified to 5500 psig by Intertek and Power Tech Labs.
NO. OF FILL POINTS 3
FILL TYPE SCBA
FILL PRESSURE 2216, 3000 or 4500 PSIG
WEIGHT 660 KG
SIZE (CM) H xD xW 173 x 97 x 86
Larger gauge panel for all feature
Inlet and outlet 4” gauges
Safety air shut off valve when door is open
Electronically controlled filling
Third Party Tested
Front Door Steel Plate
Operator Protection